Detailed comparison of PRAH-type product Xypex C-Series Admixture to PRAN-type products Hycrete W-500 & W-1000
|
Performance Standard |
| Product |
|
|
Permeability Resistance |
Compressive Strength |
Crack Sealing |
Chemical Resistance |
Set Time |
De-icer Resistance |
Moisture Vapor Emission Rate |
Electrical Conductance |
Xypex C-Series Admixture (PRAH-type product) |
|
Performance |
100% reduction against 460' water head (200 psi). |
Approx. 15% increase against control. |
Seals cracks up to 0.4mm |
Improved resistance against: 5-7% sulphuric acid, ammonium sulphate, acetone, chloride penetration and other chemicals. |
No impact with C-500. Set retardation available with C-1000 and C-2000. |
Substantial improvement in freeze-thaw durability. |
36% reduction in water vapor transmission. |
30% reduction in coulomb rating. |
|
Test |
DIN 1048 & others |
ASTM C 39 |
|
ASTM C 267 |
|
ASTM C 672 |
BBA Certificate 05/4216 - Test BS 3177 |
ASTM C1202 (modified) |
|
Additional Info |
11 independent tests available for review. Control leaked through 120mm samples - 4% Xypex-treated samples had 0mm of water penetration. |
9 independent tests available for review. |
1 independent test available for review. |
9 independent tests available for review. |
|
2 independent tests available for review. |
1 independent test available for review. |
This result based on testing by University of New South Wales using a modified ASTM C 1202. |
|
Contact us for additional information and testing data. |
|
Hycrete W-500 (PRAN-type product) |
|
Performance |
No test results available. |
No test results available. |
No test results available. |
No test results available. |
No test results available. |
No test results available. |
No test results available. |
No test results available. |
|
Test |
|
|
|
|
|
|
|
|
|
Additional Info |
|
|
|
|
|
|
|
|
|
Source: Hycrete Technical |
|
Hycrete W-1000 (PRAN-type product) |
|
Performance |
Undisclosed % reduction against 231' water head (100 psi). |
Approx. 15% decrease against control. |
Undisclosed size of cracks sealed by 56 days. |
Undisclosed resistance to chloride penetration. |
No impact. |
Meets minimum specs. |
68% reduction in water vapor transmission. |
No test results reported in documentation. |
|
Test |
ASTM D 5385 |
|
|
|
|
ASTM C 666 |
|
|
|
Additional Info |
Nelson Testing Labs, Chicago, IL |
Kansas Independent Lab Testing: 40/60 Structural Mix 0.40 W/C – 600 lbs Type I-II OPC |
Materials Service Life, LLC |
Kansas DOT |
New Jersey DOT |
300+ cycles with readings of 90+ durability - New England Transportation Consortium |
Kansas DOT: 0.42 w/c 600 lbs. cement Hycrete 2 gal./yd3 |
|
|
Source: Hycrete Testing Summary documentation |
|