Recently BASF has attempted to track Xypex-specified projects and submit their Rheomac product as an equal
to Xypex. All engineers who have reviewed the data presented on this page have concluded that BASF Rheomac
is not an equal to Xypex. This is obvious after reviewing the test data.
Xypex is not only superior in product performance, but Xypex is also superior in service.
It is true that BASF sells thousands of good products. Xypex, however sells one great
product. Because we are so specialized, we are able to provide the support needed when designing waterproof
concrete.
|
Performance Standard |
| Product |
|
|
Permeability Resistance |
Compressive Strength |
Chemical Resistance |
Set Time |
De-icer Resistance |
Moisture Vapor Emission Rate |
Electrical Conductance |
Xypex C-Series Admixture |
|
Performance |
100% reduction against 460' water head (200 psi). |
Approx. 15% increase against control. |
Improved resistance against: 5-7% sulphuric acid, ammonium sulphate, acetone, chloride penetration and other chemicals. |
No impact with C-500. Set retardation available with C-1000 and C-2000. |
Substantial improvement in freeze-thaw durability. |
36% reduction in water vapor transmission. |
30% reduction in coulomb rating. |
|
Test |
DIN 1048 & others |
ASTM C 39 |
ASTM C 267 |
|
ASTM C 672 |
BBA Certificate 05/4216 - Test BS 3177 |
ASTM C 1202 (modified) |
|
Additional Info |
11 independent tests available for review. Control leaked through 120mm samples - 4% Xypex-treated samples had 0mm of water penetration. |
9 independent tests available for review. |
9 independent tests available for review. |
|
2 independent tests available for review. |
1 independent test available for review. |
This result based on testing by University of New South Wales using a modified ASTM C 1202. |
|
Contact us for additional information and testing data. |
|
BASF Rheomac 300D |
|
Performance |
40% reduction against undisclosed water head/psi. |
7% increase against control. |
No test results reported in documentation. |
No impact. |
No test results reported in documentation. |
No reduction in water vapor transmission. |
No change against control. |
|
Test |
Modified DIN 1048 |
ASTM C 39 / C 39M |
|
|
|
ASTM F 1869 |
ASTM C 1202 |
|
Additional Info |
No independent testing reported in documentation. |
No independent testing reported in documentation. |
No independent testing reported in documentation. |
No independent testing reported in documentation. |
No independent testing reported in documentation. |
No independent testing reported in documentation. |
No independent testing reported in documentation. |
|
Source: BASF Rheomac 300D Product Data documentation |
|